Load-bearing glass beams up to 14.4 m

Grand Hall – Place Ville Marie, Montréal, Canada

For the Grand Hall at Place Ville Marie in Montréal, sedak produced 15 roof insulating glass units measuring up to 2.5 × 15 m and 18 load-bearing Glass Beams as eight-ply laminates up to 14.4 m long. Four 14-ply laminates support the cantilevered entrance canopies. The exceptional dimensions and glass build-ups required precise lamination, edge quality, and connection areas so that the roof glass, beams, and supports work together precisely as a Structural Glass system.

Insulating glass units for the roof glazing

sedak produced 15 roof insulating glass units measuring up to 2.5 × 15 m. Their exceptional length placed high demands on flatness, dimensional accuracy, edge seal, edge quality, and handling. For the horizontal application, the glass build-up and bearing areas had to be precisely coordinated with the load-bearing Glass Beams below.

Load-bearing structure with glass beams

17 Glass Beams produced as eight-ply laminates measuring up to 1 × 14.4 m perform the primary load-bearing function of the all-glass roof. Across this length, the individual glass panes, interlayers, edges, and connection areas had to be precisely aligned. The beam supports were structurally integrated into the adjacent walls, allowing the substantial load-bearing structure to visually recede. The roof insulating glass units and Glass Beams therefore work together as a coordinated Structural Glass system.

Transparent structural design

For the two entrance canopies, sedak produced four Glass Beams as 14-ply laminates measuring up to 0.8 × 5.5 m. The substantial glass build-ups perform structural functions within the cantilevered structures, which project up to 4.2 m beyond the facade plane. Structural Glass is therefore carried consistently from the main roof into the entrance areas.

Maximum precision for glass beams

For load-bearing Glass Beams, fabrication quality is determined by the details. The structural requirements are specified by the facade contractor and facade engineer and are implemented precisely during fabrication of the glass laminates. These include, for example, holes for stainless-steel connections that must pass accurately through every glass layer of the laminate.

Production becomes particularly demanding when the individual panes within a laminate have different lengths. Each glass pane is processed according to its individual geometry and positioned precisely within the multi-ply Glass Beam. Holes, edges, pane offsets, and connection areas must all be precisely coordinated.

The eight-ply Glass Beams for the Grand Hall, measuring up to 14.4 m long, demonstrate this precision on an exceptional scale. Planning data is translated into load-bearing glass units with connection details fabricated precisely for integration into the facade and roof structure.

Detail of glass construction at glass roof of the Grand Hall at Place Ville Marie in Montreal.

Ausgezeichnetes Structural Glass: Die Grand Hall am Place Ville Marie erhielt 2020 bei den ENR Global Best Projects die Auszeichnung „Best Project“ in der Kategorie Specialty Construction.

infos + facts

ArchitectureSid Lee Architecture | MSDL
Executionseele | Techniverre
GlassGlass roof, glass beams | flat
UmfangRoof: 15 IGU | max. 2.5 × 15 m
Primary load-bearing structure: 17 glass beams | 8-ply laminates | max. 1 × 14.4 m
Entrance canopies: 4 glass beams | 14-ply laminates | max. 0.8 × 5.5 m

To the project list

FAQ: Glass Beams - Grand Hall

Glass Beams

What is the function of the glass beams?

The Glass Beams are load-bearing glass units positioned below the roof insulating glass units. At the Grand Hall, eight-ply laminates measuring up to 14.4 m long perform the primary load-bearing function of the roof. Their supports are integrated into the adjacent walls.

Glass Beams

Why is producing 14.4 m long glass beams so demanding?

At this length, the individual glass panes and interlayers must be aligned precisely. Dimensional accuracy, edge quality, lamination, and connection areas must be controlled across the entire unit so that the beam, supports, and roof insulating glass units fit together precisely during installation.

Glass Beams

What is special about the entrance canopies?

For the cantilevered entrance canopies, sedak produced four Glass Beams as 14-ply laminates measuring up to 0.8 × 5.5 m. The canopies project up to 4.2 m beyond the facade plane and are structurally supported by the substantial glass beams.

Glass Beams

What role does edge quality play in load-bearing glass laminates?

In load-bearing Glass Beams and multi-ply laminates, the glass edge is a key aspect of fabrication quality. The individual panes within a laminate must be precisely processed and aligned with one another. With exceptional lengths and substantial glass build-ups in particular, edge quality becomes a critical production parameter.

When glass becomes the structure

sedak produces large-format Glass Beams, multi-ply laminates, and insulating glass units for demanding Structural Glass applications. We evaluate format, glass build-up, lamination, edges, connection areas, and further processing into complex glass units at an early stage of the project.

Discuss a Structural Glass Project